Abstract

A non-contact method based on light reflection was developed to detect quantity-insufficiency information of the tablet counting machine in medicine packaging industry. The incident light beam coming from a detection unit illuminates the detection area. A detector embedded in the detection unit collects the reflected light rays. If one tablet-missed event happens, the detector will output intensive pulse signal. By analyzing the gathered signal, the detection device can recognize that there is not a tablet in current pit. High signal-to-noise ratio was observed in the experiment, so the recognition is readily accomplished. The detection device has been applied in practical industry. It reduces the omission rate low to one hundred-thousandth, far less than three thousandth under best vision monitoring by human.