Vol. 43, Issue 2, pp. 261-270

Vol. 43 Issue 2 pp. 261-270

Evaluation of error in the performance of power corrected ophthalmic lenses

Gerardo Trujillo-Schiaffino, Didia Patricia Salas-Peimbert, Marcelino Anguiano-Morales, Daniel Malacara-Doblado, Javier Vega-Pineda

Keywords

ophthalmic lenses, refractive correction error, Hartmann test

Abstract

In this work, we describe a new method for assessing the refractive correction error in power corrected ophthalmic lenses. The ideal power distribution map corresponding to the lens design to be measured is initially obtained. Then, using some known techniques, the real power distribution map of the lens under test is obtained. Finally, the difference between the two distributions is computed, obtaining a distribution map of the refractive correction error of the lens under analysis. In the paper, we describe the implementation of the proposed method using the Hartmann test to analyze a corrected power ophthalmic lens. The technique is analyzed, and its effects on measurement resolution discussed. This method can be useful to verify the designing errors in the lab or to verify manufacturing errors of ophthalmic lenses during mass production.

Vol. 43
Issue 2
pp. 261-270

0.67 MB
OPTICA APPLICATA - a quarterly of the Wrocław University of Science and Technology, Faculty of Fundamental Problems of Technology